APC APDU10450SW unité de distribution d'énergie 48 sortie(s) CA 0U Noir
EAN : 731304439110
Référence : 8245748
APC APDU10450SW, Commutable, 0U, Monophasé, verticale, Noir, LCD
4 275,00 €
HT
4 275,00 € TTC
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
-
Fréquence d'entrée AC50 - 60 Hz
-
Poids du paquet15,4 kg
-
Hauteur du colis1980 cm
-
Profondeur du colis132 cm
-
Largeur du colis262 cm
-
Connexion en guirlandeOui
-
Poids12,4 kg
-
Profondeur75 cm
-
Intensité (max.)60 A
-
Largeur56 cm
-
Hauteur1826 cm
-
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
-
Empreinte carbone5004,04
-
Bouton marche/arrêt intégréNon
-
Montageverticale
-
Utilisation maximale de courant par phase48 A
-
Courant d'entrée maximum par phase60 A
-
Capacité d'alimentation/charge34600 VA
-
Tension de sortie240 V
-
Tension nominale de sortie240 V
-
Prise mâleIEC 60309
-
Taux d'humidité relative (stockage)5 - 95%
-
Tension nominale à l'entrée200 - 240 V
-
Taux d'humidité de fonctionnement5 - 95%
-
Types de sortie ACCoupleur C13, Coupleur C15, Coupleur C19, Coupleur C21
-
Température hors fonctionnement-25 - 65 °C
-
Altitude de non fonctionnement0 - 15240 m
-
Nombre de prises en sortie48 sortie(s) CA
-
Altitude de fonctionnement0 - 3048 m
-
Température d'opération-5 - 60 °C
-
Types de PDUCommutable
-
ÉcranLCD
-
CouleurNoir
-
Capacité du rack0U
-
TypeMonophasé
Single-phase