APC NetShelter Rack PDU Advanced unité de distribution d'énergie 48 sortie(s) CA 0U Noir
EAN : 731304439738
Référence : 8166903
APC NetShelter Rack PDU Advanced, Avec mesure en ligne, Metered-by-outlet, 0U, Triphasé, A mettre sur rack, verticale, Noir
2 975,00 €
HT
2 975,00 € TTC
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
-
Fréquence d'entrée AC50 - 60 Hz
-
Dispositifs de protection électriqueSurcharge
-
Poids du paquet12,6 kg
-
Hauteur du colis1980 cm
-
Profondeur du colis132 cm
-
Nombre de ports USB1
-
Largeur du colis262 cm
-
Algorithme de sécurité soutenu128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
-
Empreinte carbone16222,19
-
Hauteur1780 cm
-
Nombre de port ethernet LAN (RJ-45)2
-
Puissance max.22100 W
-
Température d'opération23 - 140 °F
-5 - 60 °C -
Nombre de phases3
-
Intensité (max.)32 A
-
Largeur56 cm
-
Profondeur75 cm
-
Poids9,6 kg
-
FormatA mettre sur rack
-
VoyantsActivité, Réseau, Énergie
-
Produits compatiblesCompatible with most NetShelter SX
enclosures and third-party racks -
Protection contre les surtensionsOui
-
Bouton de réinitialisationOui
-
Bouton marche/arrêt intégréOui
-
Micrologiciel évolutifOui
-
Connexion en guirlandeOui
-
Mise à niveau du microprogrammable viaRéseau, USB
-
Certificats de conformitéRoHS
-
Montageverticale
-
Contrôle de sortieVerrouiller, Recycler, Allumer, Eteindre
-
SurveillanceCourant, Humidité, Énergie, Temperature, Tension
-
Capacité d'alimentation/charge22100 VA
-
Sorties codées par couleurOui
-
Tension nominale de sortie230 V
-
Prise mâleIEC 60309
-
Taux d'humidité relative (stockage)5 - 95%
-
Tension nominale à l'entrée400 V
-
Taux d'humidité de fonctionnement5 - 95%
-
Types de sortie ACCoupleur C13, Coupleur C15, Coupleur C19, Coupleur C21
-
Température hors fonctionnement-25 - 65 °C
-
Altitude de non fonctionnement0 - 15240 m
-
Altitude de fonctionnement0 - 3048 m
-
Nombre de prises en sortie48 sortie(s) CA
-
Protection par mot de passeOui
-
Types de PDUAvec mesure en ligne, Metered-by-outlet
-
Longueur de câble1,8 m
-
ÉcranLCD
-
CouleurNoir
-
Capacité du rack0U
-
TypeThree-phase
Triphasé -
Approbations de conformitéCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1